Hot Product
banner

featured

OEM Famous FDM Company – Self-Supporting Aluminum Cable – Holley



Product Detail

Product Tags

We can constantly satisfy our respected customers with our good high quality, good price tag and good support due to we have been additional specialist and extra hard-working and do it in cost-effective way for1 phase smart meter, Smart communication, China Prepay Water Meters, Our final target is "To consider the most effective, To be the Best". Please experience cost-free to call with us if you have any prerequisites.
OEM Famous FDM Company –Self-Supporting Aluminum Cable– HolleyDetail:

Specifications

DESCRIPTION

UNIT

VALUE

VALUE

VALUE

VALUE

VALUE

1

GENERAL

 

3×35 + 1×16 + NA25 mm2

3×50 + 1×16 + NA35mm2

3×70 + 1×16 + NA50 mm2 

3×25 + 1×16 + NA25 mm2 

3X120 + 1X16 + NA70 mm2

 

Manufacturing standard

 

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

2

DESIGNATION

CAAI

CAAI

CAAI

CAAI

CAAI

 

Rated Voltage Uo / U

kV

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

0.6 / 1

3

TERMS OF USE

 

Maximum temperature in permanent regime.

° C

90

90

90

90

90

 

Maximum temperature in overload regime. 

° C

130

130

130

130

130

 

Maximum temperature in short-circuit mode (5 s)

° C

 250

 250

 250

 250

 250

4

CABLES GATHERING:

 

Maximum wireways, depending on the diameter of thePhase wire

Times

60

60

60

60

60

5

PHASE CABLE:

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 

Material

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated Aluminum

 

Nominal section

mm2

35

50

70

25

120

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

12

6

15

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

0.868

0.641

0.443

1.20

0.253

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.52

1.52

1.14

2.03

Minimum thickness at one point

mm

1.03

1.37

1.37

1.03

1.83

6

STREET LIGHT CABLE

 

Standard

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

NTP 370.250

 

Material

 Pure Aluminum without Coating

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 

Nominal section

mm2

16

16

16

16

16

 

Class

2

2

2

2

2

 

Minimum number of wires

No.

7

6

6

6

6

 

Maximum electrical resistance in DC at 20 ° C

Ohm / km

1.91

1.91

1.91

1.91

1.91

 

Insulation

 

Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

 

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

 

Minimum content of carbon black in XLPE

%

2

2

2

2

2

 

Minimum average thickness

mm

1.14

1.14

1.14

1.14

1.14

 

Minimum thickness at one point

mm

1.03

1.03

1.03

1.03

1.03

7

NEUTRAL CABLE SUPPORT
Standards

NTP 370.258

 NTP 370.258

 NTP 370.258

 NTP 370.258

NTP 370.258

Cable Material

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Conductivity

% IACS

52.5

52.5

52.5

52.5

52.5

Nominal section

mm2

25

35

50

25

70

Number of wires

7

7

7

7

7

Wire diameter

mm

2.13

2.52

3,023

2.13

3.57

 

Minimum tensile strength

kN

7.72

10.81

15.44

7.72

20.95

 

Nominal Mass

kg / km

68.4

95.7

136.8

68.4

191.5

 

Density at 20 ° C

kg / m3

2703

2703

2703

2703

2703

 

Electrical resistivity at 20 ° C

Ωmm2 / m

0.032840

0.032840

0.032840

0.032840

0.032840

 

Maximum electrical resistance in DC at 20 ° C

Ω / km

1.3511

0.9651

0.6755

1.3511

0.4825

 

Insulation
Material

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

Cross-linked polyethylene

XLPE

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.14

1.52

1.14

1.52

Minimum thickness at one point

mm

1.03

1.03

1.37

1.03

1.37


Product detail pictures:

OEM Famous FDM Company –Self-Supporting Aluminum Cable– Holley detail pictures


Related Product Guide:

We will make every effort to be outstanding and perfect, and accelerate our steps for standing in the rank of international top-grade and high-tech enterprises forOEM Famous FDM Company –Self-Supporting Aluminum Cable– Holley, The product will supply to all over the world, such as: Malaysia, Sri Lanka, Sudan, We have a good reputation for stable quality products, well received by customers at home and abroad. Our company would be guided by the idea of "Standing in Domestic Markets, Walking into International Markets". We sincerely hope that we could do business with customers both at home and abroad. We expect sincere cooperation and common development!

Leave Your Message
vr